MEMBRANE TL 90
Water and Moisture Barrier
Description
MEMBRANE TL 90 has been designed for the water and moisture barrier siding and curtain wall systems. It greatly contributes to the prevention of heat loss that might occur in your building allowing the passing of water vapor formed in the facade by containing the water built up and the rain coming with wind. It prevents the access of unwanted materials such as dirt, dust and bug that might form in external facades as well as preventing the access of external moisture to your building.
Tecnical Data
PROPERTY | TEST METHOD | UNITS | RESULTS | TOLERANCE |
Min. | Max. |
Length (in m) | EN 1848-2 | % | Customer request | 0 | - |
Width (in mm) | EN 1848-2 | % | Customer request | - 0,5 | +1 |
Flatness | EN 1848-2 | mm | - | - | 30 |
Mass per unit area | EN 1849-2 | gr/m² | 90 | 85 | 95 |
Reaction to fire | EN 13501-1 | Class | E | |
Water permeability | EN 1928 | Class | W1 | - | - |
Water vapor permeability | EN 12572 | m | 0,03 | 0,031 | 0,038 |
Maximum Longitudinal Tensile Strength | EN 12311-1 EN 13859-1 | N/5cm | 350 | 355 | 348 |
Maximum Longitudinal Breaking Elongation | EN 12311-1 EN 13859-1 | % | 85 | 75 | 95 |
Maximum Latitudinal Tensile Strength | EN 12311-1 EN 13859-1 | N/5cm | 220 | 219 | 227 |
Maximum Latitudinal Breaking Elongation | EN 12311-1 EN 13859-1 | % | 100 | 95 | 105 |
Latitudinal Tear Resistance | EN 12310-1 EN 13859-1 | N | 95 | 83 | 105 |
Latitudinal Tear Resistance | EN 12310-1 EN 13859-1 | N | 140 | 128 | 166 |
Air permeability | EN 12114 | m /(m²hr.50Pa) | Air-proof | - | - |
Dimensional stability (Length & Width) | EN 1107-2 | % | 0,3 & 0,5 | - | - |
Flexibility in low temperature | EN 1109 | °C | - | - | - |
UV radiation and artificial aging by exposure to temperature | EN 1297% EN 1296 | Increasing value | Aged / new product | - | |
Maximum tensile force (MD) | EN 12311-1 | % | - | - | - |
Maximum tensile force extension (MD) | EN 12311-1 | % | - | - | - |
Maximum tensile force (XD) | EN 12311-1 | % | - | - | - |
Maximum tensile force extension (XD) | EN 12311-1 | % | - | - | - |
Water permeability | EN 1928 | class | W1 | | |
ADDITIONAL PROPERTIES | | | | |
Temperature resistance: | - | °C | 60 | -30 | 100 |
UV Rays resistance | - | Ay | 3 | - | 4 |
Water-permeability | EN 20811 | m | Water-proof | - | - |
Wind permeability | - | - | Wind-proof | - | - |
Application
Flexible sheets - For water isolation - Descriptions and properties of substrates -Part 1: Used as substrate for the intermittent roofing sheets
Flexible sheets - For water isolation - Descriptions and properties of substrates - Part 2: Used as substrate for the walls
Package
Size (m) : 1,60 x 100
Weight :90 g/m²
Roll weight : 13.5 kg
Packing : 80m² - 160m²/ Rulo